YSAV201M 5.7 inch LCD Screen Display Medical Transport Ventilator is gas driving and Electrical control which combines the function of time, volume switch and pressure restrict, it is mainly used to the seriously ill patient and breath support to guarante
  • ModelYSAV201M
  • BrandYSENMED
  • PriceGet Price
  • MOQ1
  • Ship FromFrom Guangzhou, China
  • ShippingAny shipping terms convenient for customers
  • Share:
    Description Get Price Review(0)

    Feature:
    5.7 inch LCD Screen Display Medical Transport Ventilator is gas driving and Electrical control which combines the function of time, volume switch and pressure restrict, it is mainly used to the seriously ill patient and breath support to guarantee the patient get through the most dangerous time and support to the basic disease therapy; it provides substitute to irreversible respiratory muscle disease or irreversible damage to upper airway, maintain the ventilation function of patient; supply ventilation assistance during the resume period from disease or after operation. 

     
    Specification:
    Display mode                  High-definition 5.7” LCD screen display
    Ventilation mode               IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
    Ventilation parameters           Tidal volume         50~1500ml
    Rate                 2~99bpm
    SIMV rate            2~20bpm
    I:E                  2:1~1:8
    Inspiratory trigger pressure -1.0~2.0 kPa 
    PEEP                0~2.0 kPa
    Pressure range        1.0~6.0 kPa
    SIGH          1.5 times the inspiratory time
    Parameters for ventilation monitoring  tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
    Security Alarm System
    Airway pressure alarm           upper limit setting range       1.0~6.0 kPa
    low limit setting range        0.4~2.0 kPa
    Per-minute ventilation volume alarm    upper limit setting range       3.0~30L/min
    low limit setting range        1.0~10L/min
    Sustained high-pressure alarm     it will give alarm when stress have consistently 
    been higher than 2.5 kPa 
    Suffocation alarm               it will give sound and light alarm if there is no 
    tidal volume input for 15 seconds
    Power alarm
    Power                          AC 220V±10%     50Hz±1Hz
                                   UPS, Storage battery