Patient Monitors

Categories

15 inch Touch Screen Medical ETCO2 Multi Parameter Monitor YSPM90D

Model: YSPM90D
  • ModelYSPM90D
  • BrandYSENMED
  • PriceGet Price
  • MOQ1
  • Ship FromFrom Guangzhou, China
  • ShippingAny shipping terms convenient for customers
  • Share:
    Description Get Price Review(0)

    1.15" high resolution color TFT LCD display;
    2.13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
    3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
    4. SPO2 can testing for 0.1% Weak;
    5. RA-LL impedance Respiration;
    6. Trend Coexist Display;
    7. OxyCRG DyNamic View Display;
    8. Bed to Bed view Display;
    9. Networking capacity ;
    10. Options of printing, IBP, VGA and EtCO2;
    11. UP to 4 hours working capacity of built_in rechargeable battery;
    12.15" high resolution color TFT LCD display;
    13. Large volume of tabular and graphic trends information storage and easy to recall;
    14. Anti-ESU, anti- defibrillator;
    15. Capture dynamic waveforms.

    Technical specification
    Specifications:

    ECG

    Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
    Lead selection: I, II, III, avR, avL, avF, V,
    Waveform: 2 ch
    Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
    Lead selection: I, II, III,
    Waveform: 1 ch
    Gain: ′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV, auto
    HR and Alarm
    Range
    Adult: 15 ~ 300 bpm
    Neo/Ped: 15 ~ 350 bpm
    Accuracy : ± 1% or ± 1bpm,which great
    Resolution: 1 bpm
    Sensitivity: > 200 (uV P-P)
    Differential Input Impedance: > 5 MΩ
    CMRR
    Monitor: > 105 dB
    Operation: > 105 dB
    Diagnosis: > 85 dB
    Electrode offset potential: ±300mV
    Leakage Current: < 10 uA
    Baseline Recovery: < 3 S After Defi.
    ECG Signal Range: ±8 m V ( Vp-p )
    Bandwidth
    Surgery: 1 ~ 15 Hz
    Monitor: 0.5 ~ 35 Hz
    Diagnostic: 0.05 ~ 100 Hz
    Calibration Signal: 1 (mV p-p), Accuracy:±5%
    ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
    ARR Detecting
    Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC,
    TACHY, BRADY, MISSED BEATS, PNP, PNC
    Alarm: Available
    Review: Available

    RESPARATION

    Method: Impedance between R-F(RA-LL)
    Differential Input Impedance: >2.5 MΩ
    Measuring Impedance Range: 0.3~5.0Ω
    Base line Impedance Range: 0 – 2.5 KΩ
    Bandwidth: 0.3 ~ 2.5 Hz
    Resp. Rate
    Measuring and Alarm Range
    Adult: 0 ~ 120 rpm
    Neo/Ped: 0 ~ 150 rpm
    Resolution: 1 rpm
    Accuracy : ±2 rpm
    Apean Alarm: 10 ~ 40 S

    NIBP

    Method: Oscillometric
    Mode: Manual, Auto, STAT
    Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
    Measuring Period in STAT Mode: 5 Min
    Pulse Rate Range: 40 ~ 240 bpm
    Alarm Type: SYS, DIA, MEAN
    Measuring and alarm range
    Adult Mode
    SYS: 40 ~ 270 mmHg
    DIA: 10 ~ 215 mmHg
    MEAN: 20 ~ 235 mmHg
    Pediatric Mode
    SYS: 40 ~ 200 mmHg
    DIA: 10 ~ 150 mmHg
    MEAN:20 ~ 165 mmHg
    Neonatal Mode
    SYS: 40 ~ 135 mmHg
    DIA:10 ~ 100 mmHg
    MEAN:20 ~ 110 mmHg
    Resolution Pressure:1mmHg
    Accuracy Pressure Maximum Mean error: ±5mmHg
    Maximum Standard deviation: ±8mmHg
    Overpressure Protection
    Adult Mode: 297±3 mmHg
    Pediatric Mode: 240±3 mmHg
    Neonatal Mode: 147±3 mmHg

    SpO2

    Measuring Range: 0 ~ 100 %
    Alarm Range: 0 ~ 100 %
    Resolution: 1 %
    Accuracy : 70% ~ 100% ±2 %
    0% ~ 69% unspecified
    Actualization interval: about 1 Sec.
    Alarm Delay: 10 Sec.
    Pulse Rate
    Measuring and Alarm Range: 20~300bpm
    Resolution: 1bpm
    Accuracy : ±2bpm

    TEMPERATURE
    Channel: 2
    Measuring and Alarm Range: 0 ~ 50 °C
    Resolution: 0.1°C
    Accuracy : ±0.1°C
    Actualization interval: about 1 Sec.
    Average Time Constant:<10 Sec.


    IBP
    Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
    Measuring and alarm range
    ART: 0 ~ 300 mmHg
    PA: -6 ~ 120 mmHg
    CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
    P1/P2: -10 ~ 300 mmHg
    Press Sensor
    Sensitivity: 5 uV/V/mmHg
    Impedance: 300-3000Ω
    Resolution: 1 mmHg
    Accuracy : ±2% or ±1mmHg, which great
    Actualization interval: about 1 Sec


    tandard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
    Optional: Nellcor SpO2, EtCO2,IBP, Touch screen, Thermal Recorder,Wall mount, Trolley, Central station,HDMI

     