Email: export@ysenmed.com
TEL: +86-020-34174486
MOB: +86-18928872752
Home > Medical X Ray Machine > Floor-mounted Analog X-ray > 200mA Medical X-ray Machine YSX200

200mA Medical X-ray Machine YSX200

General radiography, Filter-ray-filter radiograph.
  • Model: YSX200
  • Brand:YSENMED
  • Price: Inquiry
  • Goods click count:853
  • 销量:最近售出 0
  • Rank:: (已有0条评论)
  • gifts for buying:0 Integral
  • MOQ:1
  • Ship From:China Guangdong
  • Shipping: Within 10-15 working days.
Quantity: -+

Product details

Shipping methods

Payment methods

200mA Medical X-ray Machine YSX200

200mA Medical X-ray Machine

USE: General radiography, Filter-ray-filter radiograph


Unit Configuration 
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator


Function
The unit can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones in lying


Feature
1. meter-indicating
2. single-table single tube
3. single-phase, full wave rectification
4. stationary anode x-ray tube assembly
5. X-ray tube filament s voltage regulator, space charge compensator
6. Radiograph plain table wimple structure and easy assembling


MAIN TECHNICAL INDEXES

ITEM CONTENTS INDEX (YSX200)
Demand of power supply Capacity Two-phase 30KVA
Voltage Frequency 380V/220V   ±10%50HZ ±0.5Hz
Intemal resistance 0.75Ω(380V)0.25Ω(220V)
power supply Adjustable range 380±10% at220V being adjustable continuously
Radiograph Voltage 50-100KV  being  adjustable  continuously
current Small focus:50mA100mA,   Big focus:50Ma 100mA  200mA  300mA
time 0.04~6.35s 23grades together grading a according to R10 coefficient
High-voltage generator Capacity 20KVA(instantaneous)
Max DC output voltage 100KV
Max DC output current 200mA
X-Ray tube Model XD51.20-40/100
Focus Small focus 1×1mm  big focus2×2mm
Radiographic table Length*width*height of bed surface 2000mm×665mm700mm
Moving range of bed surface 640mmin Length,200mmin breadth
Ray-filter of table Travel in length ≥500mm
Grid density N=28
Convergence distance f。=100cm
Grid ratio r=8
Column of X-ray tube unit Moving Longitudinally along Radiographic table 1000mmor 1800mm
Distance to friend as moving up and down (along column) 650~1800mm
Rotary around the center of cross arm ±180°
Rotary around the shaft line of X-ray annular tubes -10°~60°~  +120°
Max size of cassette 356mm×432mm(14×17)

Note: We will make another notice if the contour of product and technical parameters will be changed
Net Weight:                 Gross: 695             Packing Size: 230*112*111


Previous: 300mA Medical X Ray Machine YSX300
Next: 20kW/200mA High Frequency X-ray Machine Unit YSX200G
Shipping methods
Payment methods
Get Price
Write down your demand below and we will contact you within 24h!
Your Name: *
Company Name: *
Address: *
Email: *
Phone: *
Contents: *
Code: captcha *